Categories
PVC Single Core Cables Class T2 (105°C), ISO 6722 Class B
STANDARD USE
Single core cables for electric cabling and systems inside vehicles.
OPERATING TEMPERATURE
-40°C +105°C (3000 hrs).
Data sheet More infoTechnical details:
Conductors
Stranded bare copper (Cu-ETP1) conductors ISO 6722, FCA Procurement specification MS.90034, CEI 20-29 cl.5, EN 60228, IEC 60228, VDE 0295 cl.5 ref.Insulation
“Lead free” Polyvinylchloride (PVC), temperature rating up to 105°C (class T2, ISO 6722 class B) oil and fuel resistant ISO 6722, FCA Procurement specification MS.90034.Colour code: differently coloured.
Operating Temperature
-40°C +105°CBending radius
4 times overall diameter of cable.Operating voltage
300VFlame Retardant test
ISO 6722,FCA Procurement specification MS.90034.
CODICE / CODE | SEZIONE NOMINALE / NOMINAL CROSS SECTION (mm2) | N° DI FILI* / N° OF STRANDS* | DIAMETRO CAPILLARE MASSIMO / MAX DIAMETER OF SINGLE WIRE (mm) | RESISTENZA ELETTRICA MASSIMA @20°C / MAX ELECTRICAL RESISTANCE @20°C (Ohm/km) | DIAMETRO NOMINALE / NOMINAL DIAMETER (mm) |
---|---|---|---|---|---|
0.22 | 7 | 0.21 | 81.00 | 1.20 | |
0.35 | 7 | 0.26 | 52.00 | 1.30 | |
0.50 | 16 | 0.21 | 37.10 | 1.60 | |
0.75 | 24 | 0.21 | 24.70 | 1.80 | |
1.00 | 32 | 0.21 | 18.50 | 2.10 | |
1.50 | 30 | 0.26 | 12.70 | 2.30 | |
2.50 | 50 | 0.26 | 7.60 | 2.90 | |
4.00 | 56 | 0.31 | 4.70 | 3.70 | |
6.00 | 84 | 0.31 | 3.10 | 4.20 | |
10.00 | 80 | 0.41 | 1.82 | 6.00 | |
16.00 | 126 | 0.41 | 1.16 | 7.90 | |
25.00 | 196 | 0.41 | 0.75 | 9.40 | |
35.00 | 266 | 0.41 | 0.53 | 11.60 |