Categories
Multibus PVC
STANDARD USE
Robotic cable for industry automation with different impedance twisted and shielded pairs, according to Profibus, DevicenetTM, Interbus standards, UL-CSA approval.
Data sheet More infoTechnical details:
Cable Structure
Profibus 150 Ohm pair: (2x0,34)SN-ST2 DevicenetTM 120 Ohm pairs: 2x(2x0,34)ST
2 Interbus 100 Ohm pairs: 2x(2x0,25)SF
2 power element pairs: 2x(2x1)SF
1 protective core (Yellow/Green): 1x1
Conductors
Flexible stranded tinned copper (Cu-ETP1)UL 1581, CEI 20-29 cl.5, VDE 0295 cl.5, EN 60228, IEC 60228 ref.
Insulation
PolyolefinTwisted pair colour code
Profibus: Red, Green
DevicenetTM: (White, Blue); (Red, Blue)
Interbus: (Grey, Pink); (Yellow, Green)
Power: (Red, Black); (Blue, Brown)
Protecitve core: Yellow/Green
Shield on every single pair
Profibus:Aluminium/Polyester tape and tinned copper braid: optical coverage ≥ 85%
DevicenetTM:
Tinned copper braid: optical coverage ≥ 85%
Interbus:
Tinned copper helically wound: optical coverage ≥ 90%
Power elements:
Tinned copper helically wound: optical coverage ≥ 90%
Assembling
Non woven protective tape.Jacket
Flame retardant and oil resistant Polyvinylchloride (PVC) UL 1581, CEI 20-11 cl. TM2, EN 50363 ref.Colour code: Violet Ral 4001.
Electrical Conductor Resistance
0,25 mm2 (24AWG): < 94,2 Ohm/Km0,34 mm2 (22AWG): < 59,4 Ohm/Km
1 mm2 (18AWG): < 20 Ohm/Km
Pair Capacitance (Nominal)
Profibus: 30 pF/mDevicenetTM: 40 pF/m
Interbus: 50 pF/m
Characteristic Impedance
Profibus: 150 OhmDevicenetTM: 120 Ohm
Interbus: 100 Ohm
Operating Voltage
30 VOperating Temperature
-30°C +80°CBending radius
7 times overall diameter of cable.Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2, UL 1581 cable flame test, FT1 test.UL-CSA Approval (E235078)
AWM Style 2571 80°C 30 V – CSA I/II A/B 80°C 30 V FT1SISTEMA / SYSTEM | CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|---|
[(2x0,34)SN-ST+2x(2x0,34)ST+2x(2x0,25)SF+2x(2x1)SF+1x1] | 14,5 |