Categories
CANopen PVC
STANDARD USE
Twisted pairs shielded cables for interconnection of industrial electronic appliances in embedded systems, for dynamic applications in industrial drag chains, UL-CSA approval.
Data sheet More infoTechnical details:
Conductors
Extraflexible stranded bare or tinned copper (Cu-ETP1) UL 1581, VDE 0295 cl.6 ref.Insulation
PolyolefinTwisted pair colour code: DIN 47100 ref.
Optional First Shield
Aluminized tape.Overall Shield
Tinned copper braid with stranded tinned copper drain wire.Optical coverage: ≥ 85%
Assembling
Non woven tapeJacket
Flame retardant and oil resistant Polyvinylchloride (PVC) UL 1581, CEI 20-11 cl. TM2, EN 50363 ref.Colour code: Violet Ral 4001.
Operating Voltage
30 VElectrical Conductor Resistance
22AWG: < 59,4 Ohm/Km21AWG: < 43,6 Ohm/Km
Pair Capacitance
50 pF/mCharacteristic Impedance
120 OhmTransmission Rate
1000 Kbit/s: up to 40 m500 Kbit/s: up to 300 m
100 Kbit/s: up to 600 m
50 Kbit/s: up to 1000 m
Operating Temperature
Dynamic application: -15°C + 80°CBending radius
10 times overall diameter of cable.Maximun Speed
180 m/minMaximun Acceleration
5 m/sec2Flex Life
from 3 to 6 million of motions(bending radius 10 times overall diameter of cable)
Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2, UL 1581 cable flame test, FT1 testUL-CSA Approval (E235078)
AWM Style 2571 80°C 30 V – CSA I/II A/B 80°C 30 V FT1SISTEMA / SYSTEM | CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|---|
(1x2x22AWG+1x22AWG)ST | 7,0 | |||
(2x24AWG)ST | 6,2 | |||
(2x2x24AWG)ST | 6,4 | |||
(2x22AWG)ST | 6,0 | |||
(2x2x22AWG)ST | 7,1 | |||
(2x21AWG)ST | 7,7 | |||
(2x2x21AWG)ST | 9,7 |