Categories
Interbus PUR
STANDARD USE
Twisted pairs shielded cables for interconnection of industrial electronic appliances in embedded systems, for dynamic applications in industrial drag chains; high flexibility, outstanding resistance to industrial oils and other chemical and mechanical agents, UL-CSA approval.
Data sheet More infoTechnical details:
Conductors
Extraflexible stranded bare or tinned copper (Cu-ETP1) UL 1581, VDE 0295 cl.6 ref.Insulation
PolyolefinTwisted pair colour code: DIN 47100 ref.
Optional First Shield
Aluminized tape.Overall Shield
Tinned copper braid with stranded tinned copper drain wire.Optical coverage: ≥ 85%
Assembling
Non woven tape.Jacket
Low friction halogen free matt flame retardant Polyurethane, hydrolysis, microbial attack, abrasion, tear, oil resistant UL 1581 ref.Color code: Violet Ral 4001
Operating Voltage
30 VElectrical Conductor Resistance
22AWG: < 59,4 Ohm/Km21AWG: < 43,6 Ohm/Km
Pair Capacitance
50 pF/mCharacteristic Impedance
120 OhmTransmission Rate
1000 Kbit/s: up to 40 m500 Kbit/s: up to 300 m
100 Kbit/s: up to 600 m
50 Kbit/s: up to 1000 m
Operating Temperature
Dynamic application: -40°C + 80°CBending radius
10 times overall diameter of cable.Maximun Speed
200 m/minMaximun Acceleration
10 m/sec2Flex Life
from 3 to 6 million of motions(bending radius 10 times overall diameter of cable)
Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2, UL 1581 cable flame test, FT1 testNon-Halogen Verification
< 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1)UL-CSA Approval (E235078)
AWM Style 20236 80°C 30 V – CSA I/II A/B 80°C 30 V FT1AWM Style 20554 80°C 30 V - CSA I/II A/B 80°C 30 V FT1
SISTEMA / SYSTEM | CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|---|
INTERBUS | [2x2x0,25]ST | 7,0 | 60 | |
[3x2x0,25]ST | 8,0 | 70 | ||
INTERBUS HYBRID | [3x2x0,25+3G1]ST | 8,2 | 110 |