Categories


Double Shielded PVC Multicore Cables Class T2 (105°C), ISO 6722, ISO 14572 Class B
STANDARD USE
Double shielded Multicore cables for electric cabling and systems inside vehicles.
OPERATING TEMPERATURE
-30°C +105°C (3000 hrs)
NOTE
Low transfer impedance.
Technical details:

Conductors
Stranded bare copper (Cu-ETP1) conductors ISO 6722, FCA Procurement specification MS.90034.Cross sect. area (mm2): from 0,22 to 2,5

Insulation
“Lead free” Polyvinilchloride (PVC), temperature rating up to 105°C (class T2, ISO 6722 class B) oil and fuel resistant ISO 6722, FCA Procurement specification MS.90034.Colour code: differently coloured.

Shield
Bare copper braid with stranded bare copper drain wire.Optical coverage: > 75%

Shield
Aluminium/PVC tape with aluminium side in direct contact with braid.
Jacket
“Lead free” Polyvinilchloride (PVC), temperature rating up to 105°C (class T2, ISO 14572 class B) oil and fuel resistant ISO 14572, FCA Procurement specification MS.90034.Colour code: Black.

Operating Temperature
-30°C +105°C
Bending radius
5 times overall diameter of cable.
Operating voltage
300V
Flame Retardant test
ISO 6722, ISO 14572,FCA Procurement specification MS.90034.

Surface transfer impedance
max 20 mohm/m (f<1 MHz)max 100 mohm/m (1 MHz< f <20 MHz)
max 3000 mohm/m (20 MHz< f <1 GHz)
CODICE / CODE | FORMAZIONE (N° conduttori x Sezione del conduttore (mm2)) / TYPE (N° of conductors x Conductor cross section (mm2)) | Ø ESTERNO MEDIO / AVERAGE OUTER Ø (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|
2 x 0.75 | 5.6 | 44.0 | |
3 x 0.75 | 6.0 | 65.0 | |
2 x 2.5 | 8.1 | 140.0 | |
Altre formazioni disponibili a richiesta / Different types available on request |