Categories

Isobus PVC
STANDARD USE
ISOBUS Cables for data transmission in Agricultural vehicles.
Data sheet More infoTechnical details:

Conductors
Stranded bare copper (Cu-ETP1)UL 1581, VDE 0295 cl.5 ref.

Insulation
PVCTwisted pair colour code: differently coloured

Jacket
Polyvinilchloride (PVC) UL 1581, CEI 20-11 Cl. TM2, VDE 0207 Cl. YM2 Ref.Colour code: Black Ral 9005

Electrical Conductor Resistance
0,50mm²: < 40,1 Ohm/Km2,5mm²: < 7,98 Ohm/Km
6mm²: < 3,30 Ohm/Km
10mm²: < 2,15 Ohm/Km

Working Voltage
300/500V
Working Temperature Fixed Installation
-40°C +105°C
Bending Radius Fixed Installation
8 times overall diameter of cable
Flame Retardant Test
ISO 6722SISTEMA / SYSTEM | CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|---|
2x6+2x2,5+1x4x0,50 | 15,6 | 410 | ||
2x10+2x2,5+1x4x0,50 | 16,4 | 484 |