Categories
PVC Sensor Shielded Cables
STANDARD USE
Extraflexible cables for linking control, servo, sensor and photoelectric cells, suitable to be connected with normal, PNP, NPN circular plugs like Escha, Lumberg or equivalent. Dynamic applications in industrial drag chains, with small external dimensions, high flexibility and good resistance to industrial oils.
Data sheet More infoTechnical details:
Conductors
Extraflexible bare copper (Cu-ETP1)standard: according to UL 1581, VDE 0295 cl.6.
Insulation
Polyvinylchloride (PVC) UL 1581 ref.Colour code:
2x: blue, brown
3x: black,blue, brown
4x: black,blue, brown, white
5x: black,blue, brown, white, grey
6x: black,blue, brown, white, grey, pink
(or on request)
Assembling
Non woven tape.Overall Shield
Tinned copper braid.Optical coverage: ≥ 85%
Assembling
Non woven tape.Jacket
Flame retardant and oil resistant Polyvinylchloride (PVC) UL 1581, CEI 20-11 cl. TM2, EN 50363 ref.Colour code:
Grey Ral 7001
Grey Ral 7035
Black Ral 9005
Yellow Ral 1021 DESINA
(or on request)
Electrical Conductor Resistance
0,14 mm2: < 140 Ohm/Km0,25 mm2: < 79 Ohm/Km
0,34 mm2: < 57 Ohm/Km
0,50 mm2: < 39 Ohm/Km
0,75 mm2: < 26 Ohm/Km
1 mm2: < 19,5 Ohm/Km
Operating Voltage
300 VTest Voltage
1500 VOperating Temperature
Dynamic application: -15°C + 80°CBending radius
8 times overall diameter of cable.Maximun Speed
180 m/minMaximun Acceleration
10 m/sec2Flex Life
from 3 to 6 million of motions(bending radius 10 times overall diameter of cable)
Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2, FT1 testNo Flame propagation test
CEI 20-22/2, EN 60332-3-22 CAT.A, IEC 60332-3-22 CAT.AUPON REQUEST
UL-CSA Approval (E235078)
AWM Style 2095 80°C 300 V – CSA I/II A/B 80°C 300 V FT1AWM Style 2464 80°C 300 V – CSA I/II A/B 80°C 300 V FT1
AWM Style 20167 80°C 300 V – CSA I/II A/B 80°C 300 V FT1
Optional Jacket
Low friction halogen free matt flame retardant Polyurethane, hydrolysis, microbial attack, abrasion, tear, oil resistant UL1581 ref.Polyurethane jacket UL-CSA Approval (E235078)
AWM STYLE 20549 – CSA I/II A/B 80°C 300 V FT2CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|
2x0,14 | 4,0 | 12 | |
3x0,14 | 4,3 | 15 | |
4x0,14 | 4,5 | 22 | |
5x0,14 | 4,6 | 28 | |
6x0,14 | 4,8 | 34 | |
17x0,14 | 8,0 | 82 | |
2x0,25 | 4,5 | 20 | |
3x0,25 | 4,8 | 31 | |
4x0,25 | 5,1 | 42 | |
5x0,25 | 5,4 | 51 | |
6x0,25 | 6,0 | 62 | |
8x0,25 | 6,7 | 75 | |
2x0,34 | 4,4 | 23 | |
3x0,34 | 5,0 | 42 | |
4x0,34 | 5,4 | 50 | |
5x0,34 | 5,7 | 58 | |
6x0,34 | 6,0 | 48 | |
8x0,34 | 6,9 | 86 | |
2x0,50 | 5,1 | 46 | |
3x0,50 | 5,7 | 48 | |
4x0,50 | 6,2 | 52 | |
2x0,75 | 5,7 | 50 | |
3x0,75 | 5,8 | 53 | |
4x0,75 | 6,7 | 68 | |
2x1 | 6,0 | 58 | |
3x1 | 6,6 | 60 | |
4x1 | 7,1 | 80 |