Categories

Low capacitance twisted pair double shielded cables for EIA RS-485 application
STANDARD USE
Cables for control, audio, computer.
Impedance: 120 Ω
Maximum data transmission rate: 10 Mbit/sec.
Technical details:

Conductors
7-stranded tinned copper conductors28AWG (7x36AWG)
24AWG (7x32AWG)
22AWG (7x30AWG)

Insulation
PolyethyleneColour code according to DIN 47100 (or on request)

Shield
Aluminium/polyester tape helically wound, tinned copper drain wire and tinned copper braid.Optical coverage braid: 70% standard
>85% on request

Jacket
Polyvinylchloride (PVC)Colour: grey or on request

Electrical Conductor Resistance
0,09 mm2(28AWG): <237 Ohm/Km0,22 mm2 (24AWG): <93 Ohm/Km
0,34 mm2 (22AWG): <55 Ohm/Km

Working Temperature
-15°C + 80°C
Bending Radius
15 times overall diameter of cable
Working Voltage
300 V
Test Voltage
1500 V
Flame Retardant Test
Standard: CEI 20-35 (IEC 332.1) Ref.
Surface Transfer Impedance
optical coverage braid shield 70%: max 50 mohm/m (f<10MHz)optical coverage braid shield >85%: max 20 mohm/m (f<10MHz)

Capacitance
cond/cond: 42 pF/mCODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|
1x2x0,22 | 5,7 | ||
2x2x0,22 | 7,1 | ||
3x2x0,22 | 7,2 | ||
(2x2x0,22+1x0,22)ST | 5,9 |